Hygiene is of priority when handling
breast milk and all parts that come into
contact with it. The pump should
therefore only be used in a clean
and sterile condition.
All accessories and parts, apart from the
pump unit 2, must be thoroughly cleaned in
water, sterilised and quickly dried immediately
after each use.
7.1 Cleaning
1. Clean all parts, except the pump unit 2, in a
sink or washbasin
available washing up liquid.
Only the NUK Breast Milk Container is suitable for
dishwashers,
but
discoloration of the material may occur in rare
cases.
2. Wipe the pump unit 2 with a damp cloth. This
cleaning is sufficient because the pump unit
does not come into immediate contact with
the milk.
1. Place the overflow protection 5 in the upper
opening of the suction cap 6 (fig.
Caution:
The
protection must be inserted
so
that
the
connector
between the rubber ring and
the fastening is pointing to
the suction cap.
2. Press the lid 4 firmly onto
the overflow protection until it clicks into place
all the way round. It may require a little effort
at first to press the lid on completely (fig.

7. Cleaning and Sterilising

using commercially
please
note
that
slight
8. Assembly
).
overflow
3. A label is provided on the breast milk container
for you to write the date on which the milk
was expressed. This label can be wiped with a
sponge or cloth and written on again.
7.2 Sterilising
Before sterilising, clean as described in "7.1
Cleaning".
1. Sterilise all parts except the pump unit 2:
– in the NUK Steam Steriliser or
– boil for 5 minutes.
Note: When boiling (sterilising) always check
that there is sufficient liquid in the pan in order
to avoid damaging the teat and bottles (a
boiling time of about 5 minutes is sufficient).
The pump unit 2 must not be boiled or
sterilised, as it contains components that could
be damaged by this process.
Caution! Do not use a microwave for
sterilisation, as otherwise the material may be
damaged.
Important! The accessories and parts must be
allowed to cool fully before using again.
(Figures
to
3. Put the lip valve 8 onto the lower opening in
the suction cap 6 (fig.
4. Screw the suction cap 6 onto the breast milk
container (fig.
5. Take the pump unit 2 and
push the intake fitting of the
lid 4 completely into the
suction connector on the
pump unit 2 (fig.
6. Push the pump unit 2 firmly onto the suction
cap 6 until the coupler 3 clicks audibly into place
in the suction cap (fig.
).
7. Position the silicone cushion 7 on the suction
cap funnel 6 (fig.