Signal LED
green
yellow
red and continuous tone
red flashing (fast) and
intermittent sound
Detecting Metal Objects
After switching on, the signal LED 2 lights up green.
Position the measuring tool on/against the surface being detected and
move it sideways.
– If no metal object is visible in the base material, then the signal LED 2
continues to illuminate green and no signal tone sounds.
– When the measuring tool comes closer to a metal object, the signal LED
2 first lights up yellow and changes to red the closer it comes to the met-
al object. As soon as the signal LED lights up red, a signal tone is also
emitted, the pitch of which rises the closer it comes to the metal object.
– Over a metal object, the signal LED 2 illuminates red and a signal tone
is emitted at maximum pitch.
 Even with a yellow signal LED 2, a metal object may be located be-
low the sensor area. Small or low-lying metal objects are located in
the vicinity of the sensor or the wall material impairs the measurement
results.
After moving over the surface the first time, the posi-
tion of the metal object is only roughly indicated. If you
move the measuring tool over the metal object several
times, the object detection will become increasingly
precise. After moving over the metal object several
times (without lifting the measuring tool from the base
material), its position can be indicated very accurate-
ly: if the signal LED 2 illuminates red and the signal
tone sounds, the metal object is below the sensor area. When the pitch of
the signal tone is highest, the metal object is located below the centre of
the sensor.
Bosch Power Tools
Explanation
no object detected
– metal object in the vicinity of the sensor
– small or low-lying metal object within
the sensor area or
– impairment of the sensor due to
unfavourable wall material
metal object detected in the sensor area
"live" wire/conductor detected
1 609 92A 3FD | (5.8.16)