Herunterladen Inhalt Inhalt Diese Seite drucken

Gemü R693 Original Einbau- Und Montageanleitung Seite 44

Motorgesteuerte membranventile
Vorschau ausblenden Andere Handbücher für R693:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Important:
If the diaphragm is not screwed
into the adapter far enough, the
closing force is transmitted directly
onto the diaphragm pin and not
via the compressor. This will cause
damage and early failure of the
diaphragm and thus leakage of the
valve. If the diaphragm is screwed
in too far no perfect sealing at the
valve seat will be achieved. The
function of the valve is no longer
ensured.
Important:
Incorrectly mounted diaphragm
may cause valve leakage /
emission of medium. In this case
remove the diaphragm, check the
complete valve and diaphragm and
reassemble again proceeding as
described above.
The compressor is loose.
It contains spring washers (DN 32 / DN 40:
8 pieces - DN 50: 10 pieces).
Insert spring washers that have fallen out as
shown in the following pictures:
DN 32 / DN 40:
R693
Actuator
spindle
Spring washers
Com-
pressor
44 / 56
DN 50:
Diaphragm size 25 - 40 (DN 32 - 50):
Compressor and actuator flange seen from
below:
C
D
Place the compressor loosely on the
actuator spindle, fit the grooves D into the
guides C. The compressor must be able to
be moved freely between the guides!
Actuator
spindle
Spring washers
Com-
pressor
D
C

Kapitel