Failure: The foam formation decreases after a
certain period of time.
Cause: In the course of time the aquarium
completes the running-in phase; the water is
cleaner and the skimmable substances are
reduced.
Remedy: The skimmer has been dimensioned
correctly so that sufficient performance is still in
reserve. The airscrew can be opened a little to
improve the sensitivity.
Cause: The water inlet or the Hydrofoamer or the
nozzle system are soiled.
Remedy: Clean the water inlet at the lowest point
of the skimmer, or clean the pump and nozzle;
alternatively close the airscrew by one turn and
then open again. It also may become necessary
to remove, disassemble and clean the skimmer.
Disfonctionnement
produite diminue après une certaine période.
Raison : Après un certain temps, l'aquarium
nouvellement installé sort de sa phase de
démarrage, l'eau devient plus propre et la
quantité de substances à écumer diminue.
Solution : L'écumeur se trouve ainsi correctement
dimensionné et de telle manière à garder une
certaine réserve de puissance. Le débit d'air
peut être légèrement augmenté de manière à
augmenter la sensibilité de l'appareil.
Raison : Entrée d'eau ou Hydrofoamer ou système
d'injection colmaté.
Solution : Nettoyez l'entrée d'eau en partie
inférieure de l'appareil ou nettoyez la pompe et
la buse d'injection ou fermez la vis d'air d'un tour
puis ouvrez à nouveau. Un entretien complet de
l'appareil peut aussi s'avérer nécessaire dans
ce cas de figure.
: