1. The FWL sensor is inoperative.
1. The door is not closed properly.
2. Defective connection between door
lock and PCB.
3. Defective door lock.
1. The heater is inoperative. An
acoustic warning signal sounds at the
end of the washing programme.
1. The rotational speed is not 0, but no
speed is detected within 3 seconds or
the speed is below 20 rpm, 5 tries.
1. Abnormal AD-value of the sensor
within 2 successive seconds.
1. The rotational speed is not 0, but:
measured speed > set speed + 80.
(longer than 3 seconds).
2. The rotational speed is set to 0, but
increases
rather
(exceeds 10 rotations within 3
seconds).
than
decreases
65
running to drain the water.
2. Contact the aftersales service.
FWL sensor error.
1. Contact the aftersales service.
Door lock error.
1. Close the door properly.
2. Otherwise contact the aftersales
service.
Heater error.
1. Contact the aftersales service.
No motor speed feedback.
1. Contact the aftersales service.
Temperature sensor error.
1. Contact the aftersales service.
Short circuit in the motor (SCR)
1. Contact the aftersales service.