Herunterladen Inhalt Inhalt Diese Seite drucken

Setting The Spray Gun; Setting The Required Spray Pattern; Setting The Amount Of Material; Setting The Amount Of Air - Wagner Finish Control 3500 Plus Originalbetriebsanleitung

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

  • DEUTSCH, seite 1
EN
SETTING THE SPRAY GUN /STARTING OPERATION/
Mordants, glazes, im-
undiluted
pregnations, oils
Clear varnishes, syn-
observe manufac-
thetic enamels, col-
turer's instructions
oured paints, alkyd
resin varnishes
Primers, radiator
observe manufac-
paints, hammer ef-
turer's instructions
fect enamels
Anti-rust paints, spe-
observe manufac-
cial-effect paints
turer's instructions
Multicolor paints,
observe manufac-
textured paints
turer's instructions
7

SETTING THE SPRAY GUN

7.1

SETTING THE REQUIRED SPRAY PATTERN

Attention:
Never pull trigger while adjusting the air
cap settings.
2 different spray jet shapes can be set by turning the air cap
(fig. 3, 1)
Only turn the air cap in
the direction of the arrow,
since otherwise the union
nut can come loose.
A
horizontal flat jet
B
vertical flat jet
The controller (Fig. 4, 1) also allows the user to switch between
a wide ( ) and narrow (
7.2
SETTING THE AMOUNT OF MATERIAL (FIG. 5)
The material volume can be adjusted incrementally from 1
(minimum) to 12 (maximum) by turning the material volume
control (Fig. 5, 1).
18
FineSpray spray
attachment
(brown) recom-
mended
WallSpray spray
attachment
(white) recom-
mended
  for vertical surfaces
  for horizontal surfaces
) spray jet.
FinishControl 3500 Plus
7.3
SETTING THE AMOUNT OF AIR (FIG. 6)
Turn the air volume control (Fig, 6, 1) clockwise to increase the
air volume or anti-clockwise to reduce the air volume (note
arrow on body of gun).
Setting the air and paint flow rate correctly is im-
portant for atomisation, overspray and working
speed.
7.4

ALIGN THE FEED TUBE

If the feed tube is positioned correctly, the container
contents can be sprayed without almost any residue.
When working on lying objects:
Turn the feed tube forwards. (Fig. 7 A)
Spraying work when working on overhead objects:
Turn the feed tube rearwards. (Fig. 7 B)
8

STARTING OPERATION

Before connecting to the
mains supply make sure that
the mains voltage corre-
sponds to the operating volt-
age on the rating plate. The
unit must be connected with
a properly earthed shock-
proof socket.
1. Unscrew the container from the spray attachment.
2. Pour in the prepared coating material.
Do not overfill the
container.
3. Fit the appropriate filter to the feed tube depending on the
coating material used (Fig. 8, 1)
Low-viscosity coating materials  Fine filter (red)
Viscous coating materials
4. Align the feed tube. (Fig. 7)
5. Screw the container firmly onto the spray attachment.
6. Connect spray attachment and FC 3500. (Fig. 2)
7. Plug in the power cable.
8. The device is now ready for operation.
MAX
 Coarse filter (white)
Inhaltsverzeichnis
loading

Inhaltsverzeichnis