7.3 General faults:

Recognised fault
Deviation between the
grease layer depth in
inspection window and the
measured depth of grease
layer
7. Errors and Malfunction
Fault
Acoustic signal and flashing
Fault
Faulty function caused by
the faulty measurement
Cause
Faulty modem reception
Cause
- Faulty sensor installation
- Positioning during
installation
- Faulty initial initialisation
- Dirt deposited on the sensor
56
Remedy
Step 1: Check basic reception
possibility;
Step 2: If no reception is possible
then a modem cannot be used;
if reception is basically possible,
replace the modem
Remedy
- Tighten the cable a little and
then tighten the screw
connection by hand
- Take the type of separator
into account
- Re-calibration of the sensor
- Check the position of the
sensor
- Set the type of grease
- Set the type of grease and
clean the sensor