7.3 General faults:
Recognised fault
Text message cannot be
sent and/or remote servicing
is not possible

7.4 System faults

Recognised fault
Odour pollution
Water in the service room
In the case that a control unit alarm notification can not be acknowledged, keeping the alarm button pressed for 5 seconds
will initiate a master-reset.
7. Errors and Malfunction
Fault
Faulty function of remote
servicing
Cause
Leak in the cable duct through
faulty installation
Leak in the cable duct through
faulty installation
57
Cause
- Sensor is in the blind spot
- Grease separator type /
and/or system type not set
correctly
Faulty modem reception
Remedy
Tighten the cable screw connection in
the tank wall so that it is odour-proof
(see the operating instructions of your
grease separator as well)
Tighten the cable screw connection in
the tank wall so that it is "odour"proof
Remedy
- Reposition the sensor
(see Page 11)
- Correct settings
Step 1: Check basic reception
possibility;
Step 2: If no reception is possi-
ble , then a modem cannot
be used; if reception is basi-
cally possible, replace the
modem