Safety
2.1

General safety instructions

WARNING
Live parts!
Electrical components may only be mounted or dismantled by an electrically skilled person.
After replacing components, a safety check (visual inspection, measurement of resistances and residual currents,
etc.) must be carried out according to the national regulations for electrical safety.
NOTICE
Disconnect system from energy sources!
Ensure that the electrical components are disconnected from the electrical power supply during the work.
2.2
Personnel - qualification
In order to guarantee the long-term safety of the system, only the following activities may be performed, in accordance with
the qualification of the person carrying out the activity.
Person
Operating company
Technical expert, (familiar with,
understands operating instructions)
Technical specialist, (technical worker,
in accordance with installation instruc-
tions and execution standards)
Qualified electrician (accord-
ing to the national regula-
tions for electrical safety)
2.3

Intended use

This sensor is intended for connection either to the enclosed SonicControl control unit or to an AutoMix&Pump control unit.
It can be installed in the following tank types:
Freestanding EasyClean free grease separator
Euro type Freestanding grease separator.
EasyClean ground grease separator installed in the ground, with and without deeper installation
A cable penetration set (art. no. 917823) is always required for installation in the ground. In case of a retrofit, if the cable duct
has already been laid, the bracket with the extension pipe is sufficient (art. no. 917836).
2.4
Assemblies and function overview
Item
Component
no.
(1)
Extension pipe (accessories)
(2)
Bracket for sensor
(3)
Sensor
(4)
Marking for static level
(5)
Lower sensor finger
(6)
Drilling template
(7)
Pipe penetration seal (accessories)
(8)
Fixing part for clips
(9)
Cable penetration sleeve for installation in the
ground (accessories)
(10)
Slidable clips size 8 (accessories)
016-286
Approved activities on KESSEL systems
Visual inspec-
tion, insert plug
Emptying, cleaning
(inside), functional check
Installation instructions
Installation, replacement, mainte-
nance of components, commissioning
Electrical installation
11 / 52