7.3 General faults::

Recognised fault
Deviation between the
grease layer depth in the
inspection window and the
measured depth of grease
layer
Text message cannot be
sent and/or remote servicing
is not possible
7. Errors and Malfunction
Fault
Faulty function caused by
faulty measurement
Faulty function of remote
servicing
Cause
- Faulty sensor installation
- Positioning during
installation
- Faulty initial initialisation
- Dirt deposited on the sensor - Check the position of the
- Sensor is in the blind spot
- Grease separator type /
and/or system type not set
correctly
Faulty modem reception
60
Remedy
- Tighten the cable a little and
then tighten the screw
connection by hand
- Take the type of separator
into account
- Re-calibration of the sensor
sensor
- Set the type of grease
- Set the type of grease
Clean the sensor
- Reposition the sensor
(see Page 11)
- Correct settings
Step 1: Check basic reception
possibility;
Step 2: If no reception is
possible, then a modem
cannotbe used; if reception is
basically possible, replace the
modem