Herunterladen Inhalt Inhalt Diese Seite drucken

Kessel SonicControl Anleitung Für Einbau, Bedienung Und Wartung Seite 46

Fettschichtdickenmessgerät
Vorschau ausblenden Andere Handbücher für SonicControl:
Inhaltsverzeichnis

Werbung

Caution:
The SonicControl's
B
cable should not be
in the way or above
C
any of the sensor
probes.
D
Procedure for installing the SonicControl
grease separator.
1. Open the separator cover.
2. Attach the drilling template stop at the bot-
tom end of the upper section, mark 2 holes
on the upper section (A) through the drilling
template and pre-drill these using a 6 mm
diameter drill.
3. Screw the 2 stainless steel screws provided
into the upper section in such a way that a
gap of approx. 25mm remains between the
screw head and the upper section.
4. If the separator is installed deep in the
3. Installation and Assembly
2
A
ground, you can also use the pipe provided
(D) as an extension. To do this, fasten the
pipe (D) to the retaining clips (C) and fas-
ten the SonicControl sensor using the size 8
clips (E) provided.
5. Clip the sensor into the retaining clips (C)
of the installation bracket (B) and fasten the
installation bracket to the 2 screws. Then
tighten the screws so that the installation
frame has a firm seat.
6. Now adjust SonicControl on the red marking
at the sensor using the calm surface of the
water.
Caution
do not drill
through se-
aling
gasket!
1
46
The enclosed sticker serves as a reminder for
the disposer, in order to avoid damage to the
sensor during disposal.
The sticker must be attached as follows
Grease separator for free standing installation:
at eye level on the outside of the tank.
Grease separator for installation in the ground:
on the inside of the upper section.
Note: Draw the respective disposers'
attention to the sensor!

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading