7 DESCRIPTION OF INPUTS / OUTPUTS
The tables shown below describe the operation of all possible selections for both the inputs and outputs present on the board.
Message
NONE
START
PED
OPEN
CLOSE
OPEN_PM
CLOSE_PM
ELOCK_IN
PHOTO_1
PHOTO_2
SAFETY_1
SAFETY_2
STOP / SAS_INPUT
OPEN_INT
OPEN_EXT
AUX_IN
FCA_1
FCC_1
FCA_2
FCC_2
SAFETY_INHIBITION
RESET
20
INPUTS (IN / EXP_IN)
Not used.
N.O. input start. In case of action, this results in the opening or closing. It may function in "inversion" (P049=0)
or "step-by-step" (P049=1) modality.
N.O. pedestrian start. In case of action, this results in the partial opening of the gate. The adjustment of the
pedestrian pace can be set with P043.
N.O. input open. In case of action, this results in the partial opening of the gate.
N.O. input close. In case of action, this results in the closing of the gate.
Dead man N.O. input open The gate opens for the amount of time in which the button is pressed.
Dead man N.O. input close The gate closes for the amount of time in which the button is pressed.
Electric lock activation N.O. input. In case of action, this leads to the activation of the "LOCK" output of the
board, see P062.
N.C. input. Photocell 1. To select the operating mode, see P050. If not used, bridge the input.
N.C. input. Photocell 2. To select the operating mode, see P051. If not used, bridge the input.
N.C. input. Safety edge 1. To select the operating mode, see P067. If not used, bridge the input.
N.C. input. Safety edge 1. To select the operating mode, see P068. If not used, bridge the input.
N.C. contact. (SAS_INPUT): If connected to WARN_FIX / SAS_OUTPUT of a second control unit, causes the
"bank door" to operate (disabling the opening of the second door until the first is not fully closed).
Stop N.C. input. In case of action, this stops the movement during any manoeuvre. If this is not used, bridge
out the connection.
Internal OPEN command, causes the internal traffic light to switch when the gate reaches its open position. If
an OPEN_EXT command is also received before the gate starts to close it will process this before the automatic
close time begins.
External OPEN command, causes the external traffic light to switch when the gate reaches its open position. If
an OPEN_INT command is also received before the gate starts to close it will process this before the automatic
close time begins.
Input for the control of the AUX_OUT output.
Motor 1 opening end stop N.C. input If not used, disable the input with the corresponding parameter.
Motor 1 closing end stop N.C. input If not used, disable the input with the corresponding parameter.
Motor 2 opening end stop N.C. input If not used, disable the input with the corresponding parameter.
Motor 2 closing end stop N.C. input If not used, disable the input with the corresponding parameter.
N.C. input SAFETY inhibition. When open, it causes the by-pass of the SAFETY inputs, which are ignored even
if activated.
N.C. contact. Triggers the resetting of the control unit.