13.2 Process Interface Command Reference

All received messages which are sent because of the following commands will be sent without
"start"/"stop" at the beginning or ending of the string.
13.2.1 t Command (Asynchronous Trigger)
t
Command
Description
Executes trigger. The result data is send asynchronously
Type
Action
Reply
*
!

13.2.2 T? Command (Synchronous Trigger)

T?
Command
Description Executes trigger. The result data is send synchronously
Type
Request
Reply
Process data within the configured layout
!
Note
Result data can be sent via EtherNet/IP (data type: SINT) or
TCP/IP (data type: ASCII) (→ 9.3).
3D Sensor
Trigger was executed, the
device captures an image
and evaluates the result.
● Device is busy with an
evaluation
● Device is in an invalid
state for this command,
e.g. configuration mode
● Device is set to a
different trigger source
● No active application
Trigger was executed, the
device captures an image,
evaluates the result and
sends the process data.
● Device is busy with an
evaluation
● Device is in an invalid
state for this command,
e.g. configuration mode
● Device is set to a
different trigger source
● No active application