Herunterladen Inhalt Inhalt Diese Seite drucken

System Requirements; Function And Features; Electrical Connection; Process Connection - IFM Electronic efector250 Bedienungsanleitung

Kontursensor
Vorschau ausblenden Andere Handbücher für efector250:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

System requirements

• PC with Pentium II processor or higher, clock frequency min. 266 MHz,
recommended 500 MHz
– min. 64 MB RAM
– CD-ROM drive
– hard disk with min. 10 MB freely available hard disk memory
– USB 1.1-compatible connection
– XGA-compatible graphic card with min. 1024 x 768 pixels resolution
– PC mouse
– operating system Microsoft Windows 98 SE, ME, 2000, XP
• operating program dualis Control Panel (E2D102)
• efector dualis O2D200 - O2D205
• USB adapter cable E2D100
• 8-pole connection cable M12 for process connection (E11231)
• backlight O2D900 - O2D905

Function and features

The contour sensor uses backlight to compare the contours of an object with refer-
ence contours. Depending on the degree of conformity the test piece is classified as
being good or bad.

Electrical connection

The unit must be connected by a qualified electrician.
Disconnect power before connecting the unit.

Process connection

Connect the supply voltage of 24 V DC according to the wiring diagram of the M12
process connection indicated in the annex (page 39).
Info
When the sensor is switched on for the first time, the green LED for indicating readiness for
operation flashes. This shows that no valid configuration file has been stored in the sensor.
After parameter setting a configuration file is stored on the sensor. The green LED remains on.
If you use an external trigger source such as a diffuse reflection sensor, connect the
trigger signal with the trigger input of the sensor. The external lighting required for
the diffuse reflection mode must be triggered via the trigger output of the sensor.
One of four stored configuration files of the sensor can be selected via two switch-
ing inputs (see annex page 38).
The information about the test result is transmitted via two switching outputs (see
annex page 39).
22
All manuals and user guides at all-guides.com

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis