13.2.7 v Command

Command

Description
Type
Reply
Note
The default protocol version is „V3".

13.2.8 V? Command

Command
Description
Type
Reply
Note
13.2.9 c Command
Command
Description
Type
Reply
Note
44
v<version>
Sets the current protocol version.
The device configuration is not
affected
Action
*
!
?
<version>
2 digits for the protocol version
V?
Requests current protocol
version
Request
<current version><empty><min
version><empty><max version>
<current version>
2 digits for the currently set
version
<empty>
space sign: 0x20
<min/max version>
2 digits for the available min and
max version that can be set
c<length><configuration>
Uploads a PCIC output
configuration lasting this session
Action
*
!
?
<length>
9 digits as decimal value for the
data length
<configuration>
configuration data
Invalid version
Invalid command length
(→ 13.1.1)
● Error in configuration
● Wrong data length
Invalid command length