Herunterladen Inhalt Inhalt Diese Seite drucken

I? Command; Command - IFM Electronic O3D300 Bedienungsanleitung

3d sensor
Vorschau ausblenden Andere Handbücher für O3D300:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3D Sensor

13.2.3 I? Command

Command

Description
Type
Reply
Note
13.2.4 p Command
Command
Description
Type
Reply
Note
42
I<image-ID>?
Request last image taken
Request
<length><image data>
!
?
<image-ID>
2 digits for the image type
<length>
char string with exactly 9 digits as
decimal number for the image data size
in bytes
<image data>
image data
p<state>
Turns the PCIC output on or off
Action
*
!
?
<state> 1 digit
0: deactivates all asynchronous output
1: activates asynchronous result output
2: activates asynchronous error output
3: activates asynchronous error and
data output
4: activates asynchronous notifications
5: activates asynchronous notifications
and asynchronous result
6: activates asynchronous notifications
and asynchronous error output
7: activates all outputs
● No image available
● Wrong ID
● Invalid command length
Valid image ID:
01 - amplitude image
02 - normalised amplitude image
03 - distance image
04 - X image (distance information)
05 - Y image (distance information)
06 - Z image (distance information)
07 - confidence image (status
information)
08 - extrinsic calibration
09 - unit_vector_matrix_ex, ey,ez
10 - last result output as formatted
for this connection
11 - all distance images: X, Y, and Z
<state> contains wrong value
Invalid command length
On device restart the value
configured within the application
is essential for the output of data.
This command can be executed
in any device state.
By default the error codes will not
be provided by the device.