m Attention! Always wear safety goggles.
m Attention!
If the grinding wheel or the grinding/sanding belt be-
comes jammed during operation, please remove the
workpiece until the tool reaches its top speed again.
9.
Cleaning and maintenance
Always pull out the mains power plug before starting
any cleaning work.
Cleaning
• Keep all safety devices, air vents and the motor
housing free of dirt and dust as far as possible. Wipe
the equipment with a clean cloth or blow it with com-
pressed air at low pressure.
• We recommend that you clean the device immedi-
ately each time you have finished using it.
• Clean the equipment regularly with a moist cloth and
some soft soap. Do not use cleaning agents or sol-
vents; these could attack the plastic parts of the equip-
ment. Ensure that no water can seep into the device.
Maintenance
There are no parts inside the equipment which require
additional maintenance.
Service information
Please note that the following parts of this product are
subject to normal or natural wear and that the following
parts are therefore also required for use as consum-
ables.
Wear parts*: grinding medium
* Not necessarily included in the scope of delivery!
Spare parts and accessories can be obtained from our
Service Centre. Spare parts and accessories can be
obtained from our Service Centre.
10. Storage/Transport
Store the equipment and accessories out of children's
reach in a dark and dry place at above freezing temper-
ature. The ideal storage temperature is between 5 and
30 °C. Store the electric tool in its original packaging.
m Attention! Unplug the machine!
The appliance must unconditionally be secured against
falling or turning down during transport.
26 | GB
The appliance can be lifted on the left and right grind-
ing wheel / belt sander cover.
Power cable, flexible lamp shaft etc. should not be
used for transport purpose.
11. Electrical connection
The installed electric motor is factory connected ready
for operation. The connection meets the applicable
VDE and DlN regulations. The connection made by the
customer as well as any extension cables used must
comply with all relevant regulations.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the marking „H05VV-F".
The printing of the type designation on the connection
cable is mandatory.
AC motor
• The mains voltage must be 230-240 V~
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Motor data - type plate
www.scheppach.com
.