2.Spray tip or fluid filter may be
clogged
Basic
1.Pump frozen or hardened pain
Mechanical
2.Displacement pump connecting
rod pin
Pin must be completely pushed
into connecting rod and retaining
spring must be firmly in groove or
pump pin
3.Motor.Remove drive housing
assembly
Low Output
1.Worn spray tip
2.Verify pump does not continue to
stroke when gun trigger is released
3.Prime valve leaking
4.Suction tube connections
5.Electric supply with volt meter
Mater must read 220-240 Vac.Low
voltages reduce sprayer
performance
6.Extension cord size and length
2.Relieve pressure,then Then
clear clog or lean gun filter
1.Thaw sprayer if water or
water-based pain has frozen
in sprayer.Place sprayer in
warm area to thaw. Do not
start sprayer until thawed
completely.If paint hardened
(dried)in sprayer replace
pump packing
2.Push pin into place and
secure with spring retainer
3.Replace motor if fan won't
turn
1.Relieve pressure,Replace
tip
2.Service pump
3.Relieve pressure,Then
repair prime valve
4.Tighten any loose
connections.Check o-ring
on suction tube
5.Reset building circuit
breaker, replace building
fuse.Repair electrical outlet or
try another outlet
6.Replace with a
correct,grounded extension
card