Herunterladen Diese Seite drucken

Beko OIC 21000 Gebrauchsanleitung Seite 13

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation
and connection
Productcanonlybe installedand connected
in accordance with the statutory installation
rules.
Electrical
connection
Connect t he productto a groundedoutlet/line
protected by a fuse of suitable capacity as stated
in the "Technicalspecifications" t able. Havethe
groundinginstallationmadeby a qualified
electrician while using the product with or
withouta transformer,Ourcompanyshallnot be
liable for any damages that will arise due to
usingthe productwithouta groundinginstallation
in accordance
with the local re ulations.
DANGER:
The product must be connected to the
mains supply only by an authorised and
qualifiedperson.Theproduct's
warrantyperiodstarts onlyaftercorrect
installation.
Manufacturer s hallnotbe heldresponsible
for damages arisingfrom procedures
carried out by unauthorisedpersons,
DANGER:
The power cable must not be clamped,
bent or trapped or come into contact
with hot parts of the product.
A damaged powercablemustbereplaced
by a qualified electrician. Otherwise,there is
risk of electric shock, short circuit or fire!
Connection mustcomplywith national
regulations.
Themainssupplydata mustcorrespond to
the dataspecifiedon the typelabel of the
product. Openthe front door to see the type
label.
Power cable of your product must comply
with the valuesin "Technicalspecifications"
table.
DANGER:
Beforestartinganywork onthe
electrical installation, disconnect the
productfrom the mainssupply.
There is the risk of electric shock!
Connecting the power cable
. If it is not possible to disconnect all poles in
1
the supply power, a disconnection unit with
at least3 mm contactclearance(fuses,line
safetyswitches,contactors)mustbe
connectedandall the polesof this
disconnection unit must be adjacent to (not
above)the product in accordance with IEE
directives. Failureto obey this instruction
may cause operational problems and
invalidate the product warranty.
Additional p rotectionby a residual c urrentcircuit
breaker is recommended.
If a cable is su
BROWN
GREEN / YELLOW
2.
For single-phase connection, connectthe
wires as identified
Brown/Black cable= L (Phase)
Blue/Grey cable= N (Neutral)
Green/yellow cable= (E)
Installing the product
1. Slidethe ovenintothe cabinet,align and
secureit while makingsurethat the power
cable is not broken and/or tra
Secure the oven with 2 screws as illustrated.
with the
roduct:
TERMINAL BLOCK
BLUE
SUPPLY CORD
below:
(Ground)
ed.
13/EN