Bosch EMS plus Bedienungsanleitung Seite 4

Vorschau ausblenden Andere Handbücher für EMS plus:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 62
Общ преглед на сервизното меню
– Op. hours for comp. heat.
– Op. hours for comp. cool.
– Op. hours for comp. DHW
– Op. hours for comp. pool
– Number of heating starts
– Number of cooling starts
– Number of DHW starts
– Number of pool starts
Energy consump.
– Total
– Electric auxiliary heater
– Total
– Heating
– DHW
– Pool
– Compressor
– Total
– Heating
– DHW
– Cooling
– Pool
– 24h: ventil. current
– 30d: ventil. current
Energy supplied
– Total energy suppl.
– Heating energy suppl.
– DHW energy suppl.
– Emitted cooling energy
– Pool energy suppl.
Solar
– Solar sensor
– Solar yield
Outdoor temp
– Outside temp. curve
– Outdoor temp
– Wireless outside temp.
Internet
– IP connection
– Server connection
– Connected network
– IP address
– SW version
– Login data
– MAC address
System information (показват се само активните ограничения,
иначе менюто е празно)
– Heat pump status
– Compressor off. Too cold
– Comp. off. Too warm
– Max. air intake temp.
– Min. air intake temp.
– Cool. mode off. Too cold
4
– Cool. mode off. Too warm
– Max. temp. reached
– Heat p. off: Low fl. temp.
– Warm-up phase
– Max. add. heater temp.
– Anti-seizure mode
– Insuff. DHW flow rate
– Cooling circuit status
– Compressor output
– Additional heater status
– Elec. boost. heater output
– Status aux heater with mix
– Add. heat source
– Mixing valve
– El. DHW additional heater
– ESC block
– PV system
– Smart grid
– Current operation
– COP heat source
3
Общ преглед на сервизното меню
Елементите на менюто са изброени в списъка по-долу.
Service menu
Commissioning
– Country information
– Buffer cyl.
– Start configuration wizard
– Enter regional minimum outside temperature.
– VC0 valve connected
– Select add. heat appliance
– Mixed aux. heat. conn
– Add. el. heater op. mode
– Fan speed
– Supply air heat. by heat p.
– Heating circuit 1 installed
– Config. HC1 at HP
– Priority heating circuit 1
– Mixer heating circuit 1
– Mixer runtime heat circ. 1
– Heating system heat circ. 1
– Ctrl type h. circ. 1
– Rem. ctr. heat. circuit 1
– Heating circuit 2 installed... Heating circuit 4 installed
– DHW install.
– DHW circ.pump installed
– Size of freshwater station
– Freshwater station 2... 4
– Change freshwater configuration
– Ventilation installed
– Sol.therm.sys. instlld
– Solar extension module
– Pool mixing valve
– Electr. anode in cylinder
– Fuse size
– Confirming configuration
HMC310/HPC410 – 6721823257 (2020/09)