Building In

SR
TC
SR
R
A
A = Auxiliary burner
SR = Semi-rapid burner
Fig. 5
R = Rapid burner
TC = Triple Crown burner
Dimensions are given in millimeters
These hobs can be inserted in a built-in kitchen unit
whose depth is between 550 and 600 mm. The hobs
dimensions are shown in Fig. 5.
The edge of the cut out must have a minimum dis-
tance from the rear wall of 55 mm.
If there are side walls, or sides of the furniture unit
near the hob, the cut out edges must have a mini-
mum distance of 450 mm.
Hanging forniture units or hoods must be placed at
650 mm minimum from the hob.