Electrical connection

The appliance is designed to be connected to
230 V monophase electricity supply.
The connection must be carried out in
compliance with the laws and regulations in force.
Before the appliance is connected:
1. check that the main fuse and the domestic
installation can support the load (see the rating
label);
2. check that the power supply is properly earthed in
compliance with the current rules;
3. check the socket or the double pole switch used
for the electrical connection can be easily
reached with the appliance built in the forniture
unit.
The appliance is supplied with a connection cable and
the relevant plug.
The plug has to be fitted in a proper socket.
If connecting the appliance directly to the electric
system, it is necessary that you install a double pole
switch between the appliance and the electricity supply,
with a minimum gap of 3 mm. between the switch
contacts and of a type suitable for the required load in
compliance with the current rules.
The connection cable has to be placed in order that, in
each part, it cannot reach a temperature higher than
90°C.
The brown coloured phase cable (fitted in the
terminal block contact marked with "L") must always
be connected to the network phase.