Problem
Overheated Back-up Batteries
The gate doesn't move when pressing the
button
of the transmitter
The transmitting distance is too short
The Flashing light does not work
The leaves suddenly stop during moving
The leaves does not move or only move
toward
one direction
The master gate closes to the end first and
the slave gate stops, which the opening
or closing sequence is not being operated
properly
The gear motors does not run and the relay is
noisy when operating the gate opening and
closing
No remote
control
connection
G2- Online
assistance
Any question ?
For an individual answer, use our online chaton our
website
ASSISTANCE
www.scs-sentinel.com
Check the wiring connection of the batteries.
1. Check if LEDI is "ON" once press the transmitter.
2. Check if the voltage of the batteries is above 22V.
3. Check if LED2is "ON" and blinks accordingly.
4. Make sure all the wiring connections are firmly connected
to the terminals
on the PCB.
5. Make sure the fuse is workable. on the panel and power
socket.
Make sure the connecting terminals of the Antenna is firm.
Checkthe battery on the transmitter.
Check if the wiring connection of the flashing light is correct.
I. Check if the gate can be moved freely and no obstacles in
between.
2. Make sure the wiring connection of the gear motors is firm.
3. Make sure the fuse is workable.
4. Make sure no obstacle is present in the safety beam.
5. Cut off the power of the engine. Release the motor and
make sure the gate can move freely.
1. Check if the gate can be moved freely and no obstacles in
between.
2. Make sure the wiring connection of the gear motors is firm.
3. Make sure the fuse is workable.
4. Make sure the safety beam are operating properly if
installed.
5. Cut off the power of the engine. Release the motor and
make sure the gate can move freely.
6. Increase the delivered power switch 2 and 3.
Check the condition
fuse.
I. Check LEDI is blinking when pressing the remote control
key.
2. Check RFI receiver
Solutions
is 0k.