m ATTENTION!
This power tool generates an electromagnetic field dur-
ing operation. This field can impair active or passive
medical implants under certain conditions. In order to
prevent the risk of serious or deadly injuries, we recom-
mend that persons with medical implants consult with
their physician and the manufacturer of the medical im-
plant prior to operating the machine.
Safety instructions for table-top grinding ma-
chines
a)
Do not use damaged tool inserts. Check tool
attachments such as grinding discs for chip-
ping and cracks before each use. Once you
have checked and used the tool attachment,
ensure that you and all other persons in the
vicinity remain outside the plane of the rotat-
ing tool attachment and allow the device to run
for 1 min. at the maximum speed. Damaged tool
attachments usually break during this test period.
b)
The permissible rotational speed for tool at-
tachments must be at least as high as the max-
imum speed cited on the electric tool. Accesso-
ries that rotate faster than permitted can break and
fly off at high speed.
c)
Never grind on the side surfaces of the grind-
ing disc. Grinding on the side surfaces can cause
the grinding disc to break and fall apart.
Residual risks
m The machine has been built according to the state-
of-the-art and the recognised technical safety require-
ments. However, individual residual risks can arise
during operation.
• Danger of injury for fingers and hands due to the ro-
tating grinding disc.
• Hazard due to electrical power with the use of im-
proper electrical connection cables.
• Furthermore, despite all precautions having been
met, some non-obvious residual risks may still re-
main.
• Residual risks can be minimised if the "Safety in-
structions" and "Intended use" are observed along
with the complete operating instructions.
6. Technical data
Motor
Rated input
Operating mode
Motor speed
Grindstone idle speed
Grindstone
Dimensions L x W x H
Weight
Technical changes reserved!
Load factor:
A load factor of S2 30 min (intermittent periodic duty)
means that you may operate the motor continuously
at its nominal power level (150 W) for no longer than
30 minutes ON period. If you fail to observe this time
limit the motor will overheat. During the OFF period
the motor will cool again to its starting temperature.
Noise
The noise values have been determined in accordance
with EN 62841.
Sound pressure level L
Uncertainty K
Sound power level L
Uncertainty K
m WARNING
Excessive and frequent exposure to noise can lead to
hearing damage or hearing loss.
- Wear hearing protection
- Take breaks.
Total vibration values (vector sum of three directions)
determined according to EN 62841.
NOTE: The specified noise emission values have
been measured in accordance with a standardised
test procedure and can be used to compare one
power tool with another.
The specified noise emission values can also be used
for an initial estimation of the exposure.
www.scheppach.com
230 - 240 V / 50 Hz
Ø200 x 40 x Ø12 mm
460 x 310 x 355 mm
.............................63,5 dB(A)
pA
...................................................... 3 dB
pA
................................. 76,5 dB(A)
WA
...................................................... 3 dB
WA
150 W
S2 30 min
-1
1490 min
-1
115 min
9kg