4. Design
Adapter set, 7 mm spindle
Adapter sleeve, 8.5 mm spindle
Adapter sleeve, 10 mm spindle
4. Design
1
5. Prepare door (drilling template)
NOTE
Fastening in the centre is optional
Fastening in the centre is optional. The SmartHandle AX Advanced can also
be installed without this fastening system.
Use the middle fastener if you require greater stability.
ü
Pin or scriber at hand.
Drill at hand.
ü
Suitable drill bit at hand (Ø 7 mm).
ü
PH2 screwdriver at hand.
ü
1.
Insert the spindle into the mortise lock.
2
2.
Place the drilling template on the spindle.
3
3.
Align the drill template vertically using the printed scale.
4.
Mark the drill holes with mark 1.
4
5.
Remove the drilling template and rotate it 180 degrees.
5
6
6.
Place the drilling template on the spindle.
7
7.
Align the drill template vertically using the printed scale.
8.
Mark the drill hole with mark 2.
8
9.
Remove the drilling template and spindle.
9
10
10. Remove the mortise lock.
11
11.
Drill the required holes.
12
12.
Fit the mortise lock.
13
6. For door thickness X: have the
threaded rods and spindle ready at hand
ü
Caliper gauge at hand.
ü
Saw at hand.
ü
PH2 screwdriver at hand.
1.
Measure the door thickness.
14
2.
For door thickness X: screw the 50 mm screws, threaded sleeves and
threaded rods together.
15
36 / 68
SmartHandle AX Advanced Conventional installa-
3.
For X: mark the sawing points on the threaded rods and spindle.
16
17
4.
For X: Use a suitable saw to cut the threaded rods and spindle.
18
7. Installing the fitting
NOTE
Fastening in the centre is optional
Fastening in the centre is optional. The SmartHandle AX Advanced can also
be installed without this fastening system.
Use the middle fastener if you require greater stability.
ü
Door pre-drilled.
ü
PH2 screwdriver at hand.
ü
TX15 screwdriver at hand.
ü
Caliper gauge at hand.
1.
Insert the spindle protective tube and the sleeve nuts into the fastening
plate.
19
2.
Insert a spacer ring into the openings in the middle and top sleeve nuts.
20
3.
For 7 mm spindle: Insert the adapter shoe into the spindle mount on the
module support.
21
4.
Insert the module support into the fastening plate.
22
5.
Slide the module support upwards.
23
Module support snaps into place.
9
6.
Fasten the module support to the fastening plate (PH2) with the 12 mm
screws.
24
25
7.
For non-MO: insert the blank cylinder.
NOTE
Feed the blank cylinder into the hole using a screwdriver
It is difficult to position the blank cylinder correctly, especially in thick doors.
1.
Insert a screwdriver into the hole in the blank cylinder.
2.
Position the blank cylinder using the screwdriver.
26
27
8.
For non-MO: screw the blank cylinder firmly into position.
28
9.
Measure the door thickness.
29
tion SH3062/FR195