Power supply
The INU server can be supplied via 2 power sources. One
power source takes over the supply. A second power source
can be connected as an additional redundant power supply if
required.
WARNING
The low-voltage cable between the power supply
or power supplies and the INU server must not be
longer than 3 m.
Power supply
connection:
supply voltage
Current input
Cable
Required stripping:
7
1:
Connectors 1 + 2
2:
Connectors 3 + 4
via screw terminals
- 10 VDC (min.) to 28 VDC (max.)
- power consumption max. 15 W
- redundant
at 12 V:
- approx. 200 mA without load
- approx. 850 mA with full load on
the USB ports
at 24 V:
- approx. 110 mA without load
- approx. 420 mA with full load on
the USB ports