Note:
f a smoke alarm is instal ed in a kitchen, ensure it has an accessible
silence button, and install it as far away from the stove and sinkas
possibleto avoid false alarms.
l. Prioritize the installation Ofan alarm in bedrooms and walkways,and
make sure you can hear the alarm from all sleeping areas.In homes
with multiple bedrooms, install an alarm in every bedroom. f you only
install one smoke alarm in your home, install it close to al bedrooms
where possible,and not in a basement or furnace room.
2. Install an alarm above stairwaysand on everyfloor of the house.
3. Smoke, heat, and anything burning will spread horizontal y after rising
to the ceiling, so install the alarm in the middle of the ceiling where
possible.
4. If an alarm cannot be installed in the middle ofa ceiling, install it at
east 20 inches (50cm) away from all corners of a room.
5. If an alarm is instal ed on a wall, keep it between4 12 inches
(10-30cm) below the ceiling,
6. If a room or hal way is longer than 30 feet (900 crn),install multiple
alarms
in that
room.
7. When the wall or ceiling is angled, the alarm needs to be installed
within 3 feet (90 cm) of the highest wall or ceiling point (measured
horizontal y) in the room.
8. To maintain a secure and stable Wi-Fi connection,
within the router's coverage areaand make sure that there areasfew
obstacles between them as possible,
install the alarm
Placement on the Ceiling or Wall
f you install a smoke alarm in a kitchen, p ace it at least 5 feet (1.5m)
away from potential smoke or fume sources, such asstoves and furnaces.
f you install the alarm on a wall, place it at least 4 inches (10 cm) from
the highest point. Keep the device at least 5 feet (1.5m) from potential
smoke or fume sources such as stoves, furnaces, water heaters, and
space heaters.
Make sure the alarm is installed within range of the router and that
nothing is preventing smoke from reaching the alarm.