Technical data

Special voltages
NOTE!
Danger due to insufficiently dimensioned electrical installations.
Incorrectly dimensioned mains plugs, mains supply leads and fuse protection can lead to
serious damage to (or loss of) property.
DPS 2500
Mains voltage
Mains voltage tolerance
Netzfrequenz
Mains fuse protection
Primary continuous power (100 % d.c.*)
Cos phi
Operating current range (continuous)
Operating current at 10 min / 40°C (104°F)
Open-circuit voltage
Operating voltage
Degree of protection
Type of cooling
Insulation class
Dimensions (with interface) L x W x H
Weight
Marks of confirmity
Idle state power consumption at 400 V
Power source efficiency at 250 A / 70 V
* d.c. = duty cycle
Overview with
Overview with critical raw materials:
critical raw mate-
An overview of which critical raw materials are contained in this device can be found at
rials, year of pro-
the following Internet address.
duction of the
www.fronius.com/en/about-fronius/sustainability.
device
If the power source is designed to run on a special voltage, the Technical Data
shown on the rating plate apply. The mains plug and mains supply lead, and their
fuse protection, must be dimensioned accordingly.
3 x 400 V
+ / -15 %
50 / 60 Hz
35 A (slow blow)
24,3 kVA
0,99
20 - 250 A
60 % d.c.* / 250 A
100% d.c.*/ 200 A
140 V
up to 70 V
IP 23
AF
F
750 x 310 x 480 mm
29.5 x 12.2 x 18.9 in.
35.6 kg
78.5 lbs.
CE, CSA
36.1 W
89%
49