Use one of the control units listed below to check and control the sauna heater.
ƒ
This control unit is fixed to a suitable location on the cabin's external wall, and the
corresponding temperature sensor according to the installation instructions that
accompany the control units inside the sauna cabin.
The cabin lighting must be safe for sauna cabin use and installed in such a way that it
ƒ
can be used safely in a sauna cabin. Ensure that the heater is installed in compliance
with the standards and legal norms valid in your country.
The cabin door must open outward and must not have a lock that cannot be opened
ƒ
in the case of failure. We recommend magnetic or spring locks.
All electrical installations and equipment in a sauna must comply with the IEC
ƒ
60364-7-703 (DIN VDE 0100-703) norm.
1.2 Operator instruction
The operator of the sauna cabin must be instructed in the general safety instructions during
commissioning. The operator must be given a copy of the operating instructions.
Risk of electric shock
A risk to life and limb from electric shock and fire arises in the event of improper repair work.
This risk remains also after work is completed.
The housing cover must only be removed by a specialist.
ƒ
Repairs and installations must only be performed by a trained specialist.
ƒ
The system must be disconnected and removed entirely from the mains supply
ƒ
before commencing repair work.
Use only original spare parts from the manufacturer.
ƒ