II - 5 Measured Value Output

Examples of character output at the data interface

The values can be retrieved from ND 780 using a PC. In all three
examples, measured value output is started with Ctrl B (sent over
serial interface), or a switching signal at the EXT input (within
optional Auxiliary Machine Interface). Ctrl B will transmit the currently
displayed values in either Actual Value, or Distance-To-Go mode,
whichever is currently visible.

Data output using external signals

Example 1: Linear axis with radius display X = + 41.29 mm
X
=
+
4 1
.
1
2
3
4
5
11 Coordinate axis
Equal sign
2
+/– sign
3
2 to 7 places before the decimal point
4
Decimal point
5
1 to 6 places after the decimal point
6
Unit: blank space for mm, " for inches
7
Actual value display:
8
R for radius, D for diameter
Distance-to-go display:
r for radius, d for diameter
Carriage return
9
Blank line (Line Feed)
10