II - 3 Encoder Parameters
The following tables represent a partial list of encoders. These tables
describe all operating parameters which must be set for the encoders.
Most entries can be found in the operating instructions for the
encoder.
Example settings for HEIDENHAIN linear encoders with 11-µA
signals
Encoder
Signal period
CT
2
MT xx01
LS 303/303C
20
LS 603/603C
LS 106/106C
20
LS406/406C
LB 302/302C
40
LM 501
10 240
Example settings for HEIDENHAIN linear encoders with 1-V
signals
Encoder
Signal period
LIP 382
0.128
MT xx81
2
LIP 481A/481R
LIP 481X
2
LF 183/183C
4
LF 481/481C
LIF 181/181C
LIP 581/581C
LS 186/186C
20
LB 382/382C
40
LIDA 18x/18xC
VM 182
4
LIDA 10x/10xC
100
LIM 581
10 240
ND 780
PP
Reference marks
Single
Single/
1000
Single/
1000
Single/2000
Single
PP
Reference marks
–
Single
Single
Single/5000
Single/1000
Single/
2000
–
Single/1000
Single