In the event of one of the above
described protections intervening, after ascertaining
and removing the cause of the intervention, press the
“STOP” button to reset the control panel (otherwise
the signal would remain in memory preventing the
engine from starting).
Any maintenance operation on
the generator must be carried out with the engine off
and leaving it to cool down sufficiently, and must
only be carried out by authorised and suitably trained
personnel.
I.S. 6.5
Before accessing the generator,
disconnect one pole of the starter battery in order to
prevent accidental starting.
Check the oil level by means of the
graduated dipstick [Fig. 6, Ref. 2]. The level must
always be between the MAX and MIN notches on the
dipstick [Fig. 6 Ref. 1].
- The first engine oil change must be carried out after
50 hours of generator operation. For the second
and subsequent oil changes, every 200 hours is
sufficient.
- For more detailed information on engine
lubrication, consult the engine use and maintenance
manual attached to the generator.
- Dispose of the used oil or fuel in an appropriate
manner as they are polluting products.
Avoid contact of engine oil with the
skin. During maintenance operations use gloves and
protective glasses.
In case of contact with engine oil, immediately and
thoroughly wash the affected part with soap and water.