Herunterladen Inhalt Inhalt Diese Seite drucken

How To Use; Temperature Setting; Venting After Maintenance Work; Cleaning And Maintenance - clage DCX 13 Gebrauchsanleitung

E-komfortdurchlauferhitzer
Vorschau ausblenden Andere Handbücher für DCX 13:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

DCX ELECTRONIC MPS
/ DCX 13 ELECTRONIC MPS
®

3. How to use

EN
Five coloured LEDs
Temperature selection key
®

Temperature setting

The temperature selection key
peratures, that are typical for hot water applications:
"Hand wash" 35 °C, "Shower" 38 °C, "Bath tub" 42 °C, "Kitchen" 48 °C and
"Cleaning" 55 °C.
Every key press sets the temperature to the next level:
35 °C
38 °C
42 °C
Pressing the key
once again, starts the cycle all over.
The currently selected temperature is indicated by one of five coloured LEDs.

Venting after maintenance work

This instantaneous water heater features an automatic air bubble protection to pre-
vent it from inadvertently running dry. Nevertheless, the appliance must be vented
before using it for the first time. Each time the appliance is emptied (e.g. after work on
the plumbing system, if there is a risk of frost or following repair work), the appliance
must be re-vented before it is used again.
1. Disconnect the instantaneous water heater from the mains (e.g. via deactivating the
fuses).
2. Unscrew the jet regulator on the outlet fitting and open the cold water tap valve to
rinse out the water pipe and avoid contaminating the appliance or the jet regulator.
3. Open and close the hot water tap until no more air emerges from the pipe and all
air has been eliminated from the water heater.
4. Only then should you re-connect the power supply again (e.g. via activating the
fuses) to the instantaneous water heater and screw the jet regulator back in.
5. The appliance activates the heater after approx. 10 seconds of continuous water
flow.

Cleaning and maintenance

• Plastic surfaces and fittings should only be wiped with a damp cloth. Do not use
abrasive or chlorine-based cleaning agents or solvents.
• For a good water supply, the outlet fittings (special tap aerators and shower heads)
should be unscrewed and cleaned at regular intervals. Every three years, the electri-
cal and plumbing components should be inspected by an authorised professional in
order to ensure proper functioning and operational safety at all times.