Technical data
Nominal voltage [V]
Voltage tolerance [%]
Power consumption [W]
Housing
Protection
Connection
Operating temperature [°C]
Storage temperature [°C]
Rel. humidity, max. [%]
Inputs
Reset / preset
Gate (counting interruption)
Outputs
Switching voltage
Switching current
Protective components
Sensor
DZ2001
DZ2006
Counter
Counting frequency [Hz]
Displays
Light reception sensor
Function check sensor
Outputs
Counter values, parameters
Standards, guidelines
24 DC
± 10
17
plastic
IP67 (with screwed-on socket)
M12 socket, 8 poles
-10 ... 45 (DZ2001)
-20 ... +60 (DZ2006)
-25 ... +80
75, up to 35°C
24 V DC active to pin 5
24 V DC active to pin 1
2 x transistor DC pnp
supply voltage 24 V DC is switched
max. 300 mA per output
short-circuit protected
If inductive loads are switched, use
external protective components.
retro-reflective sensor laser with
polarisation filter; range: 10m
(prismatic reflector TS80)
infrared diffuse reflection sensor
range 600 mm
preset counter (2 presets)
adding / subtracting
auto-reset / preset
last value memory
max. 500
LED yellow
LED red
2 x LED green
LCD display, 7/14-segment
EMC 89/336/EEC;
EN 50081-1 / EN50082-2