LED signals / status indicators
Operation mode
LED
(blinking pattern)
1 (GN)
On
1 (GN)
Flashing (- - - - - - - - - )
2 (RD)
Off
2 (RD)
On
2 (RD)
Flashing ( - - - - - -)
2 (RD)
Flashing (- - - - - - - - - )
3 (YE)
On
3 (YE)
Off
3 (YE)
Flashing (- - - - - - )
3 (YE)
Flashing (- - - - - - - - - )
Cable length
The maximum cable length depends on the voltage drop in the lines.
The voltage range of the CSMS is 24 V +10 % / –15 %
The voltage drop depends on the core cross section, the total length of the lines
(all lines have to be considered) and the current flowing through the cable.
The exact cable length depends on the application and must be calculated in accordance with the electrical bases.
32
Event
No errors in the voltage monitoring
Errors in the voltage monitoring
(simultaneous blinking of the red)
Safety circuit is closed
Another participant has opened the safety circuit
Participant has opened the safety circuit
-> safe condition with a possible return
Participant has opened the safety circuit
-> safe condition without a possible return
(An error has been detected. The safety outputs remain enabled and
the device can only be switched on again after a power reset.)
Actuator located within easy reach, correct code
Actuator in range, false code
Actuator in range, false code
Actuator at maximum range, correct code
Triangle symbol
for orientation
Fig. 26
20.4 V – 26.4 V
Fig. 27
L
= maximum length of a CSMS system
max
LED 1 (GN) (green)
LED 2 (RD) (red)
LED 3 (YE) (yellow)