Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Ambient Conditions; Electrical Data - Balluff BVS ID-M1280 F1 Serie Betriebsanleitung

Vorschau ausblenden Andere Handbücher für BVS ID-M1280 F1 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BVS ID-M1280xF1-xx-xxx
9

Technical Data

NOTE
Further data can be found at
9.1

Ambient conditions

Ambient temperature
Storage temperature
EMC
Vibration/shock for operation inside
Degree of protection
Relative humidity
1)
Using appropriate cables or blind plugs. The enclosure rating has not been UL certified.
Vibration/shock was verified for the sensor.
NOTE
Avoid strong temperature fluctuations in a short time even within the specified ambient temperature
range. This leads to condensation on the liquid lens or to delays in automatic focusing, which in turn
reduces the reading quality of the sensor.
9.2

Electrical data

Operating voltage
Residual ripple
Rated current consumption without external load
Max. current consumption
Protective circuit
ATTENTION
Risk of equipment damage
The sensor and accessories shall be supplied by limited energy in accordance to UL 61010-1 Third
Edition, Sub. Clauses 9.4 or LPS in accordance to UL 60950-1 or Class 2 in accordance to UL 1310 or
UL 1585.
www.balluff.com
on the product page.
0 °C to +55 °C
–25 °C to +70 °C
EN 61131-2:2007
EN 61131-9:2013
EN 60068 Part 2-6/27
IP67
0 to 100%
≤ 5 %
300 mA
1.6 A
Reverse polarity protection
1)
18 ... 30 V
english 
39