BVS ID-M1280xF1-xx-xxx
9
Technical Data
NOTE
Further data can be found at
9.1
Ambient conditions
Ambient temperature
Storage temperature
EMC
Vibration/shock for operation inside
Degree of protection
Relative humidity
1)
Using appropriate cables or blind plugs. The enclosure rating has not been UL certified.
Vibration/shock was verified for the sensor.
NOTE
Avoid strong temperature fluctuations in a short time even within the specified ambient temperature
range. This leads to condensation on the liquid lens or to delays in automatic focusing, which in turn
reduces the reading quality of the sensor.
9.2
Electrical data
Operating voltage
Residual ripple
Rated current consumption without external load
Max. current consumption
Protective circuit
ATTENTION
Risk of equipment damage
The sensor and accessories shall be supplied by limited energy in accordance to UL 61010-1 Third
Edition, Sub. Clauses 9.4 or LPS in accordance to UL 60950-1 or Class 2 in accordance to UL 1310 or
UL 1585.
www.balluff.com
on the product page.
0 °C to +55 °C
–25 °C to +70 °C
EN 61131-2:2007
EN 61131-9:2013
EN 60068 Part 2-6/27
IP67
0 to 100%
≤ 5 %
300 mA
1.6 A
Reverse polarity protection
1)
18 ... 30 V
english