12. End point adjustment

Additional information about configuring the end
points
The end points must be configured for the roller shutters
to stop at the desired upper and lower positions.
It is imperative that both end points are configured,
otherwise malfunctions may occur.
Set the upper end point
1.
+
Simultaneously press and hold the
buttons.
The roller shutters travel up.
1.1
Tighten the belt slightly, until it is tensioned by the
weight of the roller shutters.
2.
+
Release the buttons, as soon as the roller
shutter reaches the desired position for
the upper end point.
The roller shutters stop and the upper
end point is stored.
68
i
If the RolloTron Basic 1100 is operated without
an end point setting, the drive will continue
to run for as long as one of the two control
buttons is actuated.
The automatic functions remain blocked
until the end point setting is configured.
ATTENTION!
Setting the wrong upper end point may lead to over-
load or damage the RolloTron Basic 1100 or the drive.
◆ Do not set the upper end point right up to the limit
stop.
◆ Release the button promptly and never allow it to
extend beyond the respective end point.
EN