Technical Specifications; Power Supply; Operating Conditions - RADEMACHER 1823 45 19 Betriebsanleitung

Rollotron basis1100
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

i

6. Technical Specifications

Power supply

Supply voltage:
Nominal power:
Consumption:
Mechanical capacity:
Nominal torque:
Maximum speed:
Maximum tractive force:

Operating conditions

Transient operation (KB):
Protection class:
Protection type:
Number of switching times: 2 (up and down)
Mains connecting cable:
Permissible ambient tem-
perature:
54
230 V ~ / 50 Hz
70 W
Standby: < 0.5 W
10 Nm
30 rpm
See page 81 / Tractive force
diagram
4 minutes
(maximum running time)
II
IP20 (only for use in dry
rooms)
2
2 x 0.75 mm
(H03VVH2-F)
0 °C to +40°C
Conduct in the event of power failure
The indicator light flashes in the event of a power
failure.
The flashing is switched off by pressing the UP ( ▲ ) or
DOWN ( t ) button.
Data retention subsequently to power failure
The configured switching times are retained after a
power failure. As soon as the power supply is restored,
the opening and closing times will be executed again.
However, the times will be offset by the duration of the
power failure.
Example:
◆ Power failure from 19:30 - 19:45 hours.
◆ The closing time was previously set to 19:30 hours.
◆ The roller shutters will close at 19:45 hours due to
the duration of the power failure.
EN