The device is clogged by
dirt and dust.
The entered Wi-Fi name
and/or password are
wrong.
The phone Bluetooth is
Device failed to connect to the
not turned on.
network.
The device is not entering
pairing mode.
The app push notification
permission is disabled.
The device is not within
the network coverage of
The app push notification is
the router.
delayed or there are no push
alerts.
The network connection
of the router and the
mobile phone is
abnormal.
The battery runs out.
The app shows that the alarm
The communication
is offline.
between the alarm and
the router is blocked or
the distance is too far.
Clean the device periodically (see
"Maintenance").
Enter the correct Wi-Fi name and password.
Turn on the phone's Bluetooth.
Press and hold the Test/Silence button on the
device for 5 seconds and its LED will flash blue to
enter the pairing mode.
Turn on the push notification permission on the
phone.
The distance between the device and the router
should be within 170 ft (50 m). Please ensure that
the device is always within the network coverage
of the router.
Make sure the network connection of the router
and the mobile phone is normal.
Replace the battery.
Reduce the obstacles between the alarm and
the router. The maximum distance between the
alarm and the router is 170 ft (50 m) in an open
environment.
The network connection
of the router and the
mobile phone is
abnormal.
The carbon monoxide
The device screen shows the
(CO) concentration
concentration value, yet the
value is currently below
app does not provide
100 ppm, and the alarm
notifications or display the
threshold time has not
concentration value.
been reached yet.
Device is in the "CO
Device screen updates
Alarm Precaution" state,
concentration value, but the
and concentration
app value remains unchanged.
hasn't increased to
higher level yet.
LED flashes yellow once every
Low battery warning.
60 seconds with 1 beep.
LED flashes yellow 2 times
Malfunction.
every 60 seconds with 2 beeps.
LED flashes yellow 3 times
End-of-life warning.
every 60 seconds with 3 beeps.
Make sure the network connection of the router
and the mobile phone is normal.
Device won't send a "CO Alarm Precaution" alert
for CO concentrations under 100 ppm to save
power and avoid disturbances. App won't
display values either. But if CO under 100 ppm
lasts for a period of time and reaches alarm
threshold, normal alarm notification is sent.
To conserve power, the app updates the
concentration value only when it rises within a
specific range (e.g., from 110 ppm to 220 ppm)
during the "CO Alarm Precaution" state.
The battery is low. Push Test/Silence button
once to silence for 10 hours. Replace the
battery immediately.
The alarm is malfunctioning. Please clean your
alarm and see if it is working normally. If not,
replace the device immediately.
The maximum lifetime (10 years) is reached. Push
the Test/Silence button once to silence for 22
hours. Replace the alarm immediately.