Unit detects CO
A CO concentration
and initiates an
ranging from 30 to
alarm.
999 ppm has been
present for a certain
time period. The LED
indicator flashes red 4
times every 5.8
seconds.
Unit detects CO
A CO concentration
(alarm not
level ranging from 30
initiated).
to 999 ppm has been
detected, but for less
than the allotted
detection period. The
LED indicator flashes
green once every 60
seconds.
4 quick beeps
Dangerous CO
repeating every
concentration is
5.8 seconds.
detected, and has
reached the alarm
status. The app will
show a "CO Alarm
Triggered" message,
and an app push
notification will be sent
to your smartphone.
Open nearby windows
and doors, and
immediately move to
fresh air.
None.
Dangerous CO
concentration
is detected, but has not
reached the alarm
status. Potentially
dangerous CO
conditions exist. The
app will show a "CO
Alarm Precaution"
message, and an app
push notification will
be sent to your
smartphone.
Please search for the
CO source first. Open
nearby windows and
doors, and immediately
move to fresh air.
Unit detected
The LED indicator
smoke and
flashes green once
initiated an
every second for 5
alarm.
seconds.
Unit detected CO
The LED indicator
and initiated an
flashes green once
alarm.
every second for 5
seconds.
2 sets of 3 red flashes
followed by 2 sets of 4
red flashes.
Test Mode
Flashes red 3 times
every 4 seconds.
Silence Mode
Flashes red 4 times
every 5.8 seconds.
None.
Alarm cancellation:
when the smoke
concentration level
drops below the alarm
threshold, the alarm
signal will stop. Then,
the alarm goes back to
the standby mode after
testing.
None.
Alarm cancellation:
when the CO
concentration level
drops below the alarm
threshold, the alarm
signal will stop. Then,
the alarm goes back to
the standby mode after
testing.
2 sets of 3 long
Press the Test/Silence
beeps followed
button.
by 2 sets of 4
quick beeps.
None.
Smoke silence mode:
After 9 minutes, the
unit will exit silence
mode.
None.
CO silence mode: After
9 minutes, the unit will
exit silence mode.