DUCTIMAX
Speed
Declared speed
Rated air flow
Available static pressure
Power input
Maximum current absorption
Total cooling capacity
Sensible cooling capacity
FCEER class
Water flow
Water pressure drop
Heating capacity
FCCOP class
Water flow
Water pressure drop
Standard coil - number of rows
Total sound power level
Inlet + radiated sound power level
Outlet sound power level
Water content - standard coil
Power supply cable type
Cross-section area of power cables
Safety fuse F
Fuses type
(1)
Water temperature 7°C / 12°C, air temperature dry bulb 27°C, wet bulb 19°C (47% relative humidity) according to EN1397:2015
(2)
Water temperature 7°C / 12°C, air temperature dry bulb 27°C, wet bulb 19°C (47% relative humidity)
(3)
Water temperature 45°C / 40°C, air temperature 20°C
(4)
Sound power measured according to standards ISO 3741 and ISO 3742
(5)
The shown section is to be considered as the minimum recommended section. The cables must be chosen in compliance with CEI - UNEL 35024/1. standard.
(E)
EUROVENT certified data
Power supply 230-1-50 (V-ph-Hz)
» 4 pipes
DUCTIMAX
Speed
Declared speed
Rated air flow DF 1R
Available static pressure DF 1R
Power input DF 1R
Maximum current absorption
Total cooling capacity DF 1R
Sensible cooling capacity DF 1R
FCEER class DF 1R
Water flow DF 1R
Water pressure drop DF 1R
Heating capacity DF 1R
FCCOP class DF 1R
Water flow DF 1R
Water pressure drop DF 1R
Total sound power level DF 1R
Additional coil DF - number of rows
Inlet + radiated sound power level DF 1R (4)(E)
Outlet sound power level DF 1R
Water content - additional coil DF 1R
Power supply cable type
Cross-section area of power cables
Safety fuse F
Fuses type
26
DUCTIMAX
min
(E)
m³/h
333
(E)
Pa
12
(E)
W
76
A
(1)(E)
kW
2,22
(1)(E)
kW
1,60
(E)
(2)
l/h
394
(2)(E)
kPa
2
(3)(E)
kW
2,54
(E)
(3)
l/h
442
(3)(E)
kPa
2
(4)
dB(A)
38
(4)(E)
dB(A)
36
(4)(E)
dB(A)
35
dm³
(5)
mm²
A
13
min
med
max
2,5,7
(E)
m³/h
109
243
(E)
Pa
10
50
(E)
W
24
57
A
0,40
(1)(E)
kW
0,92
1,70
1,86
(1)(E)
kW
0,61
1,20
1,31
(E)
(2)
l/h
160
302
(2)(E)
kPa
2
5
(3)(E)
kW
1,14
1,93
2,06
(E)
C
(3)
l/h
100
169
(3)(E)
kPa
1
2
(4)
dB(A)
28
49
1
dB(A)
26
47
(4)(E)
dB(A)
25
46
dm³
0,47
(5)
mm²
1,00
A
1
53
54
med
max
min
med
max
1,6,7
1,6,7
687
760
333
687
50
61
12
50
167
192
76
167
1,10
1,10
4,22
4,63
2,44
4,79
5,23
3,09
3,39
1,70
3,33
3,64
753
828
432
850
7
8
3
10
4,76
5,17
2,63
5,03
5,49
827
898
457
875
7
8
3
9
3
4
55
58
38
55
53
56
36
53
52
55
35
52
2,50
3,30
1,50
1,50
2
2
14
min
med
max
2,5,7
270
109
243
270
63
10
50
63
82
24
57
82
0,40
0,95
1,88
2,06
0,63
1,28
1,40
D
333
167
334
368
6
2
7
8
1,14
1,93
2,06
C
180
100
169
180
3
1
2
3
52
28
49
52
1
50
26
47
50
49
25
46
49
0,47
N07V-K
1,00
1
gG
63
min
med
max
min
5,6,7
760
1050
1163
1289
1050
61
40
50
60
40
192
235
280
332
235
2,10
6,15
6,66
7,21
6,91
4,51
4,88
5,29
4,83
D
930
1095
1191
1295
1225
12
13
16
18
20
6,68
7,22
7,80
7,18
D
955
1162
1256
1357
1248
11
12
14
16
17
3
58
61
63
69
61
56
59
61
67
59
55
58
60
66
58
2,50
N07V-K
1,50
2
gG
23
min
med
max
min
1,5,7
170
272
336
170
19
50
77
19
34
69
106
34
0,56
1,26
1,88
2,24
1,35
0,88
1,33
1,57
0,92
221
335
404
238
3
6
8
4
1,55
2,07
2,32
1,55
D
136
181
204
136
2
3
3
2
39
50
54
39
1
37
46
52
37
36
45
51
36
0,47
1,00
1
64
med
max
5,6,7
1163
1289
50
60
280
332
2,10
7,49
8,12
5,23
5,67
1333
1448
23
26
7,80
8,46
1356
1472
20
23
4
63
69
61
67
60
66
3,30
1,50
2
24
med
max
1,5,7
272
336
50
77
69
106
0,56
2,09
2,49
1,42
1,70
370
447
8
12
2,07
2,32
D
181
204
3
3
50
54
1
46
52
45
51
0,47
1,00
1