a recalibration interval of one year. Send the appliance to the following address:
Benning Elektrotechnik & Elektronik GmbH & CO. KG
Service Centre
Robert-Bosch-Str. 20
D - 46397 Bocholt
9.6 Spare parts
Fuse F 16 A, 500 V, D = 6.35 mm, L = 32 mm, part no. 749770
Fuse F 1 A, 500 V, D = 6.35 mm, L = 32 mm, part no. 749669
10. How to use the protective rubber holster
-
The safety test leads can be stored by wrapping them around the protec-
tive rubber holster  and then clipping the probes into the protective probe
holders on the rear of the holster  (see figure 11).
-
A safety test lead can be clipped into the probe holder on the protective
rubber holster  with the test probe protruding, in order to apply the probe
together with the BENNING MM 2 to a measuring point .
-
The rear tilt stand on the protective rubber holster  allows the
BENNING MM 2 to be placed standing upright (for easier display reading)
or hung up (see figure 12).
-
The protective rubber holster  can also be hung on a nail if so desired.
see Figure 11:
see Figure 12:
11. Technical data of the measuring accessories
-
Standard: EN 61010-031,
-
Maximum rated voltage to earth () and measuring category:
With push-on caps: 1000 V CAT III, 600 V CAT IV,
Without push-on caps: 1000 V CAT II,
-
Maximum rated current: 10 A,
-
Protective class II (  ), continuous double or reinforced insulation,
-
Contamination class: 2,
-
Length: 1.4 m, AWG 18,
-
Environmental conditions:
Maximum barometric elevation for making measurements: 2000 m,
Temperatures: 0 °C to + 50 °C, humidity 50 % to 80 %
-
Only use the measuring leads if in perfect and clean condition as well as
according to this manual, since the protection provided could otherwise be
impaired.
-
Throw the measuring lead out if the insulation is damaged or if there is a
break in the cable/ plug.
-
Do not touch the bare contact tips of the measuring lead. Only grab the area
appropriate for hands!
-
Insert the angled terminals in the testing or measuring device.
12. Environmental note
12/ 2023
mm_2_druck.indd 16
Winding up the safety test leads
Erecting the BENNING MM 2
At the end of the product's useful life, please dispose of the device at
collection points provided in your community.
BENNING MM 2
16
28.11.2023 15:50:46

Werbung

loading

Diese Anleitung auch für:

Mm 4