2 MΩ
20 MΩ
7.6 Continuity and Diode Testing
The accuracy indicated below is valid in the range of 0.4 V to 0.9 V.
Overload protection for diode testing: 500 V
The built-in buzzer sounds if the resistance R falls below 50 W.
Range
8.
Measuring with BENNING MM 2
8.1 Measurement preparation
The BENNING MM 2 must be used and stored only at the indicated storage and
working temperatures, avoid exposure to continuous sunlight.
-
Check the rated voltage and current indications on the safety test leads.
The safety test leads provided with the BENNING MM 2 correspond specifi-
cally to the rated voltage and current of the BENNING MM 2.
-
Inspect the test leads for damaged insulation. If the insulation is damaged,
the test leads should be discarded immediately.
-
Check test lead continuity. If the conductor in the test lead is damaged, the
leads should be discarded immediately.
-
Remove test leads from circuit to be measured before turning the rotary
switch  to select another function.
-
If the BENNING MM 2 is used near strong noise generating sources, the
display may become unstable and measurement errors may arise.
8.2 Voltage and current measurement
The maximum rated voltage that should be applied between any of the following
terminals of the BENNING MM 2 and earth ground is 600 V.
-
COM terminal 
-
Input terminal for V, Ω,
-
Input terminal for µA/ mA range 
-
Input terminal for 20 A range 
8.2.1
-
Select the appropriate range and voltage type with the rotary switch  of
the BENNING MM 2.
-
Connect the black safety test lead to the COM-terminal  of the
BENNING MM 2.
-
Connect the red safety test lead to the input terminal for V, Ω,
BENNING MM 2.
-
Connect the safety test leads to the circuit measurement points and read
the measured value on the digital display  of the BENNING MM 2.
see Figure 2:
see Figure 3:
8.2.2
-
Select the appropriate range and current type with the rotary switch  of
the BENNING MM 2.
-
Connect the black safety test lead to the COM-terminal  of the
BENNING MM 2.
-
Connect the red safety test lead to the input terminal for the µA/ mA range
 for currents up to 200 mA, or to the input terminal for the 20 A range 
for currents between 200 mA and 20 A of the BENNING MM 2.
-
Connect the safety test leads to the circuit measurement points and read
the measured value on the digital display  of the BENNING MM 2.
see Figure 4:
see Figure 5:
12/ 2023
mm_2_druck.indd 13
1 kΩ
± (0,8 % of reading + 2 digits)
10 kΩ
± (2,0 % of reading + 5 digits)
Resolution
1 mV
± (1,5 % of reading + 5 digits)
To avoid electrical shock, observe the maximum rated voltage
to earth ground!
Electrical hazard!
Maximum permissible circuit voltage for current measurement
is 500 V! If a safety fuse blows at a voltage above 500 V the
BENNING MM 2 could be damaged. A damaged tester presents
an electrical shock hazard to the user!
Voltage measurement
Direct voltage measurement
Alternating voltage measurement
Current measurement
DC current measurement
AC current measurement
BENNING MM 2
.
rms
Maximum test
Accuracy
current
, 
400 nA
0,5 V
40 nA
0,5 V
Max. open circuit
voltage
1,5 mA
3,2 V
,  of the
28.11.2023 15:50:46
13

Werbung

loading

Diese Anleitung auch für:

Mm 4