Herunterladen Diese Seite drucken

Badger Meter Dynasonics ISonic 4000 Bedienungsanleitung Seite 44

Werbung

IS-4000
0x0125
U16
0x0126
FLOAT
0x0128
FLOAT
0x012A
U16
0x012B
U32
0x012E
U16
0x012F
U32
0x0202
FLOAT
0x0204
U16
0x0205
U16
0x0206
U16
0x0226
6
Seite 42
Admin
COMMAND
Factory
CURRENTLOOP_POINTA
Factory
CURRENTLOOP_POINTB
Service
SIMULATION
Read only
RANDOM
Service
ALARM_MODE_OF_ANALOG_OUTPUT
Write only
REMOTE_LOGIN
Service
PULSE_PULSES_PER_M3
Service
PULSE_WIDTH
Service
OUT_LOW
Service
OUT_HIGH
Service
DATETIME
1: save configuration
2: restore configuration
6: save totalizers
7: clear totalizers
8: clear totalizers
14: current loop calibration point A
15: current loop calibration point B
16: current loop calibration complete
22: default save
23: remote reset
24: default restore
26: make file system
34: press key up
35: press key right
36: press key save exit
38: print screen
41: open channel – calculate upper range
42: open channel – use default water level
Dry calibration
Dry calibration
Not stored in non-volatile memory
0: 0.0%
10: + 10.0%
20: + 20.0%
30: + 30.0%
40: + 40.0%
50: + 50.0%
60: + 60.0%
70: + 70.0%
80: + 80.0%
90: + 90.0%
100: +100.0%
65408: Off
65436: -100.0%
65446: - 90.0%
65456: - 80.0%
65466: - 70.0%
65476: - 60.0%
65486: - 50.0%
65496: - 40.0%
65506: - 30.0%
65516: - 20.0%
65526: - 10.0%
Security
0: none
3: 23 mA
4: 3.5 mA
Security
Digital Output setting
Digital Output setting
OBSOLETE
OBSOLETE
Date & Time
HYB-UM-03459-DE-04
September 2023

Werbung