Description / use
PT hexagon screw K80x40 WN 1447
Electrical connection values
Data
Cable type
Remote control
LIYCY 3x0.34 mm²
Remote control
H05VV-F 3x1.0mm²
Control unit
no cable mounted
Mix & Pump
Refill inlet
Manual valve
Possible
pressure pipe
connections
Storz-B coupling
* Control unit
016-189_03
Torque Nm
5.5 ±0.5
Shield-
Type of con-
ing
nection
Yes
Control line
Schuko earthed
safety plug
no
1"
1"
DN 65, socket
weld fitting,
Plasson coupler
PN 10,
Woven hose
with 2 screw
clamps
2 1/2"
Installation and operating instructions
Spanner size
Socket 13mm
Cable
max.
Extension
length
length
15 m
100 m
Do not extend - replace
1.25 m
100 m
Do not extend length -
replace with NYM 3x1.5mm²
or Ölflex Classic 110
40 m
Installation with NYM
5x2.5mm² at max. length
(depending on control unit*
whole system - nominal
power)
21 / 92