3
Technical data
3.1
Dimensions and weights
Volumes/mass
Area / NS
Sludge trap (l)
Wastewater contents (l)
Grease storage (l)
Total volume (l)
Cold water requirements (up to
static level in l)
100% grease layer thickness
(mm)
Empty weight (kg)
Electrical connection values
Operating voltage
Mains frequency
Power
Nominal current range
Protection class (pump)
Required fuse protection
Protection class
Max. pumping height
Max. pumping capacity
(Permanent) temperature of conveyed material
Tightening torque
Description / use
PT-screw KB60x30 WN 1411
PT-screw 100x30 A2
Attachment clamp (refill inlet)
Pipe clamp D=120
Pipe clamp D=84
20 / 92
2
200
400
100
600
505
140
152
Description
Torque Nm
4.5 ±0.5
7
3
8-10
8-10
Installation and operating instructions
3
4
300
400
300
400
120
160
600
800
505
645
170
170
153
166
7
10
700
1000
650
900
280
400
1350
1900
1225
1660
210
210
217
256
Value
400 V
50 Hz
4 kW
2.5 - 6 A
IP 55
C 16
I
17 m
60 m
/h
3
max. 40 °C
Spanner size
T30
T50
ISK 10mm
Socket 13mm
Socket 13mm
016-189_03