Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Waeco CoolMatic HDC275 Montage- Und Bedienungsanleitung

Kompressor-kühlschrank
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

HDC275
12

Troubleshooting

Compressor does not run
Fault
U
= 0 V
TERM
≤ U
U
TERM
ON
Start attempt with
U
≤ U
TERM
OFF
Start attempt with
U
≥ U
TERM
ON
Electric circuit between
the pins in the compres-
sor interrupted
U
Voltage between the positive and negative terminals of the electronics
TERM
U
Cut-in voltage of the electronics
ON
U
Cut-off voltage of the electronics
OFF
EN
Possible cause
There is an interruption in the bat-
tery–electronics connection
Main switch faulty (if installed)
Additional supply line fuse has blown
(if installed)
Battery voltage is too low
Loose cables
Poor contact (corrosion)
Battery capacity too low
Cable cross section too small
Ambient temperature too high
Insufficient ventilation
Condenser is dirty
Fan defective (if installed)
Defective compressor
Troubleshooting
Remedy
Establish a connection
Replace the main switch
Replace the supply line
fuse
Charge the battery
Establish a connection
Replacing the battery
Change the cable (see
table on page 40)
Move the refrigerator to
another location
Clean the condenser
Replace the fan
Replace the compressor
49