Troubleshooting
Interior temperature too low at control level "1"
Fault
Compressor runs
constantly
Compressor runs for a
long time
Poor cooling, increase in interior temperature
Fault
Compressor runs for a
long time/continuously
Compressor does not
run often
Water in or under the refrigerator
Fault
Water is leaking into the
inside of the refrigerator.
Water is leaking onto the
floor.
50
Possible cause
Thermostat sensor has no contact to
the vaporiser
Short circuit in the thermostat line
Thermostat defective
Large quantities have been frozen in
the freezer compartment
Possible cause
Vaporiser is iced over
Ambient temperature too high
Insufficient ventilation
Condenser is dirty
Fan defective (if installed)
Battery capacity exhausted
Possible cause
The water drain duct is clogged.
Foodstuffs are preventing the water
from flowing to the collector.
There is too much water in the air
deflector.
HDC275
Remedy
Secure the sensor
Change the thermostat
Remedy
Defrost the vaporiser
Move the refrigerator to
another location
Clean the condenser
Replace the fan
Charge the battery
Remedy
Clean the drain.
Make sure that foodstuffs
do not touch the rear wall.
Clean the air deflector.