Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Waeco CoolMatic HDC275 Montage- Und Bedienungsanleitung

Kompressor-kühlschrank
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

HDC275
Unusual noises
Fault
Loud humming
13

Technical data

Item number:
Refrigerator compartment capacity:
Freezer compartment capacity:
Connection voltage:
Mean power consumption:
Power consumption at 25 °C/32 °C:
Cooling temperature range
Refrigerator compartment:
Freezer compartment:
Capacity:
Climatic class:
Relative humidity:
Constant inclination:
Dimensions:
Weight:
Inspection/certification:
The refrigerant circuit contains R134a.
EN
Possible cause
A component of the refrigerant circuit
cannot move freely (touching the wall)
There is a foreign object stuck
between the cooling unit and the wall
Fan noise (if installed)
Technical data
Remedy
Bend the component
carefully away from the
obstruction
Remove the foreign object
HDC 275
9105203898
202 l
75 l
12 Vg or 24 Vg
61 W
3.3 Ah/h / 5.1 Ah/h
0 °C to +10 °C
–18 °C to 0 °C
277 l
ST(+16 °C to +38 °C)
maximum 90 %
maximum 30°
see fig. s, page 10
Approx. 52 kg
51