Troubleshooting

11
Compressor does not run
Fault
U
KL
U
KL
Start attempt with
U
KL
Start attempt with
U
KL
Electric circuit between
the pins in the compres-
sor interrupted
Usage when the ambi-
ent temperature is too
low
U
KL
U
ON
U
OFF
36
Downloaded from
www.Manualslib.com
Troubleshooting
Possible cause
= 0 V
There is an interruption in the con-
nection between the battery and the –
electronics
Main switch faulty (if installed)
Additional supply line fuse has blown
(if installed)
≤ U
Battery voltage is too low
ON
Loose cables
≤ U
Poor contact (corrosion)
OFF
Battery capacity too low
Cable cross section too small
Ambient temperature too high
≥ U
Insufficient ventilation and/or air
ON
supply
Condenser is dirty
Fan defective (if installed)
Defective compressor
The compressor only starts up at an
ambient temperature of more than
+16 °C.
Voltage between the positive and negative terminals of the
electronics
Cut-in voltage of the electronics
Cut-off voltage of the electronics
manuals search engine
CoolMatic CRP-40
Remedy
Establish a connection
Replace the main switch
Replace the supply line
fuse
Charge the battery
Establish a connection
Replacing the battery
Replace the cable
(fig. 9, page 6)
Move the refrigerator to
another location
Clean the condenser
Replace the fan
Replace the compressor
Only switch on the refrig-
erator at an ambient tem-
perature of more than
+16 °C.